[Jan 29, 2022] DES-6322 PDF Recently Updated Questions Dumps to Improve Exam Score [Q24-Q44]

Share

[Jan 29, 2022] DES-6322 PDF Recently Updated Questions Dumps to Improve Exam Score

DES-6322 Dumps Full Questions with Free PDF Questions to Pass

NEW QUESTION 24
A company has multiple VxRail systems installed at geographically dispersed data centers They want to upgrade all their VxRail systems to the latest release- Before the upgrade, they want an inventory report of all the VxRail systems which shows the current health status and versions of all installed VxRail components.
What should be used to meet these requirements?

  • A. itrend
    Live Optics
  • B. Mitrend
    VxRail Log insight
  • C. VxRail Plugin for vCenter Server
    VxRail API
  • D. VxRail Plugin for vCenter Server
    DRM Services

Answer: B

 

NEW QUESTION 25
Which VxRail model can only be installed with static rack rails?

  • A. D Series
  • B. G Series
  • C. S Series
  • D. P Series

Answer: A

 

NEW QUESTION 26
What is a consideration when performing a VxRail software upgrade from version 4.7.xxx to version 7.0.xxx?

  • A. Secure boot must be enabled on the ESXi hosts for a successful upgrade
  • B. VxRail Manager VM must be changed to the default name to avoid an upgrade failure
  • C. External vCenter server must be upgraded after the VxRail is upgraded
  • D. vCenter Server requires a temporary IP address on a different subnet before the upgrade

Answer: C

 

NEW QUESTION 27
What is a supported witness configuration for a 3+3+1 VxRail Stretched Cluster?

  • A. Physical ESXi host with multiple VxRail clusters as witness
  • B. vSAN Witness appliance with customer provided license
  • C. vSAN Witness appliance or a physical ESXi host
  • D. Physical ESXi host with included cluster license

Answer: C

 

NEW QUESTION 28
An implementation engineer is reviewing the customer requirements for a VxRail implementation The customer has specified noncontiguous hostnames and IP addresses What option should the engineer select in the VxRail Deployment Wizard to input the hostnames and IP addresses?

  • A. Custom
  • B. Autofill - with the correct offset
  • C. Autofill - with the correct incrementor
  • D. Advanced

Answer: B

 

NEW QUESTION 29
An implementation engineer places a VxRail node into maintenance mode using the Ensure accessibility setting What is the engineer likely planning to do?

  • A. Temporary maintenance
  • B. Extensive maintenance
  • C. Permanent removal of host from cluster
  • D. Shutdown of an entire cluster

Answer: B

 

NEW QUESTION 30
A planned VxRail Stretched Cluster will have four hybrid nodes at each site. What is the recommended storage policy to ensure cross-site and local protection, using storage as efficiently as possible?

  • A. Site disaster tolerance - Dual site mirroring (stretched cluster)
    Failures to tolerate - 1 failure - RAID-1 (Mirroring)
  • B. Site disaster tolerance - None keep data on Preferred (stretched cluster) Failures to tolerate - 1 failure - RAID-1 (Mirroring)
  • C. Site disaster tolerance - Dual site mirroring (stretched cluster)
    Failures to tolerate - 1 failure - RAID-5 (Erasure Coding)
  • D. Site disaster tolerance - Dual site mirroring (stretched cluster)
    Failures to tolerate - No data redundancy

Answer: C

 

NEW QUESTION 31
What setting is used for the object space reservation in the VXRAIL-SYSTEM-STORAGE-PROFILE?

  • A. 75% Reservation
  • B. 50% Reservation
  • C. Thin Provisioning
  • D. Thick Provisioning

Answer: C

 

NEW QUESTION 32
A VxRail E560F model was delivered six months ago and is now scheduled to be installed with the target code. What is the correct order of steps to complete this task?

Answer:

Explanation:

 

NEW QUESTION 33
An infrastructure system audit will begin in two weeks All data center devices will be checked to ensure they contain the installed patches and configurations. A system engineer will update the VxRail hosts with the latest patches and remediate security vulnerabilities.
What troubleshooting resource can a user receive from Dell and use proactively to help perform the remediation tasks?

  • A. Log files
  • B. KB articles
  • C. Advisories
  • D. SolVe Online

Answer: A

 

NEW QUESTION 34
A systems engineer is tasked to configure a VxRail cluster and notices that the VxRail Deployment Wizard fails to launch. The engineer discovers that the software is corrupted.
What should the engineer do to address the issue?

  • A. Check vCenter and troubleshoot the build failure
  • B. Return the nodes to the original build state
  • C. Use the VMware Host Client and iDRAC to access the nodes for troubleshooting
  • D. Verify that the JSON file is not corrupted and has all the required values

Answer: B

 

NEW QUESTION 35
What is a benefit of using the VxRail REST API?

  • A. Automated security audits of VxRail clusters
  • B. Programmatically gather VxRail system health
  • C. Polling for vSAN performance statistics
  • D. Remote upgrades of iDRAC related software only

Answer: B

 

NEW QUESTION 36
A company needs to enable vSphere GPU capabilities on their VxRail cluster. To do so, they need to purchase a specific entitlement.
What licensing satisfies this requirement?

  • A. vSphere Enterprise Plus
  • B. vSAN Advanced Edition
  • C. vSphere Standard
  • D. vSAN Enterprise Plus Edition

Answer: D

 

NEW QUESTION 37
A VxRail Manager VM must be configured as follows:
* IP address: 192 168.10.16
* Net mask: 255.255.255.0
* Gateway: 192 168 10 254
Which command must be used?

  • A. vxrail-network -config --vxrail-address 192.166 10 16 --vxrail-netmask 255 255.255 0 --vxrail-gateway
    192.168.10.254
  • B. vxrail-prrmary -config --ip 192 168 10 16 -netmask 255 255 255 0 -gateway 192 168 10 254
  • C. vxrail-network-config --ip 192 168 10.16-netmask 255.255.255.0-gateway 192 168 10.254
  • D. vxrail-primary -config --vxrail-address 192.168.10 16 --vxrail-netmask 255 255 255 0 -vxrail-gateway
    192.168,10 254

Answer: D

 

NEW QUESTION 38
What guideline should be followed when planning bandwidth between sites hosting VM objects and the witness nodes?

  • A. 1500 MTU on the VSAN vmkernel interface
  • B. 500 ms roundtrip (< 250 ms one way)
  • C. 2 Mbps for every 1000 objects on the vSAN
  • D. 5 ms with a recommended minimum bandwidth of 10Gbps

Answer: C

 

NEW QUESTION 39
What is a consideration when expanding a VxRail cluster? (Choose two.)

  • A. 1 GbE must be hybrid and single processor node type
  • B. Expanding a cluster to 64 nodes requires a 25 GbE network
  • C. Mixing of All-Flash and all-NVMe nodes in a cluster is not allowed
  • D. G Series clusters can be expanded only with G Series nodes

Answer: B,D

 

NEW QUESTION 40
An implementation engineer is in the validation phase of a VxRail deployment with two Dell EMC ToR switches. Which command should they run on each of the ToR switches to validate that Link Aggregation has been configured according to Dell best practices for VxRail node interfaces?

  • A. show interface status
  • B. show network-policy profile
  • C. show interface
  • D. show port-channel summary

Answer: B

 

NEW QUESTION 41
From what location should NVT for VxRail be run?

  • A. Workstation on the same network as VxRail Manager
  • B. Jump server on a different network
  • C. VxRail network Top of Rack switch
  • D. Laptop connected to the first VxRail ESXi node

Answer: A

 

NEW QUESTION 42
An implementation engineer is performing a precheck on a VxRail cluster before expansion. During validation, they find out that the host is not compatible.
Use the VxRail simulator to describe why the host is Incompatible.
Note: It is necessary to close (x) the simulator window before you can select a response to this question.





  • A. bmc and bios are running older versions
  • B. Invalid vCenter 5erver license
  • C. Firmware of ESXi host needs to be updated
  • D. Insufficient number of vSphere licenses

Answer: B

 

NEW QUESTION 43
What is the recommended format for host names when using the VxRail Deployment Wizard for an External vCenter solution?

  • A. FQDN for vCenter Server
    Host name for VxRail Manager
  • B. Host name for both vCenter Server and for VxRail Manager
  • C. FQDN for both vCenter Server and for VxRail Manager
  • D. Host name for vCenter Server
    FQDN for VxRail Manager

Answer: A

 

NEW QUESTION 44
......


EMC DES-6322 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Identify REST API functionality available in VxRail and use VxRail API
  • Describe VxRail use cases, architecture, models, and software stack
Topic 2
  • Perform post-installation validation of the VxRail Cluster Configure
  • Describe VxRail pre-installation requirements and use of the configuration tools
Topic 3
  • Perform VxRail RASR factory image upgrade and reset procedures
  • Describe VxRail management, licensing, and data protection options
Topic 4
  • Describe VxRail system racking and cabling procedures
  • Describe VxRail Upgrade requirements and activities
Topic 5
  • Explain the vSAN configuration settings and configure required vSAN settings post deployment
  • Validate the network environment using the Network Validation Tool
Topic 6
  • Describe the VxRail Stretched Cluster architecture, features, and requirements
  • Describe system power up/down and setting management VLAN procedures
Topic 7
  • Explain differences in the VxRail implementation procedures for various
  • Complete a Test Plan and generate a VxRail As-Built Configuration report
Topic 8
  • Describe considerations for deploying Embedded and External vCenter
  • VxRail Pre-deployment Tasks and Hardware Installation
Topic 9
  • Describe how to Implement licenses for a VxRail cluster
  • VxRail Cluster Expansion and Stretched Clusters
Topic 10
  • Describe VxRail troubleshooting resources and their uses
  • VxRail Network Environment Requirements and Initialization
Topic 11
  • Describe VxRail appliance scale-out best practices and the cluster expansion process
  • Perform a VxRail initialization using the VxRail First Run Wizard

 

100% Updated EMC DES-6322 Enterprise PDF Dumps: https://www.braindumpspass.com/EMC/DES-6322-practice-exam-dumps.html