2022 Latest NCS-Core Exam Dumps Recently Updated 195 Questions
Nutanix NCS-Core Real 2022 Braindumps Mock Exam Dumps
NEW QUESTION 28
An administrator receives an alert in Prism indicating that interface eth2, on an AHV host is receiving many CRC errors. Aftertogging into the problematic host, the following command is run to show the indicated output:
What is causing this issue?
- A. A misconfigured bond
- B. The interface is incorrectly configured with Jumbo Frames
- C. Incorrect link speeds on the switch
- D. A physical layer network problem
Answer: B
Explanation:
Explanation
Ref:
rx_crc_errors are caused either by faults in layer 1 (in the past, we have seen failed twinax cables and incorrect types of fibre being used), or issues with jumbo frames on the network. In an environment with
10Gig switches that use cut-through forwarding (Cisco Nexus, Arista, Cisco devices using IOS default to Store and Forward switching), any packets that come into the switch will get forwarded out the destination interface once the switch has read the destination MAC address. If that packet has an MTU over what is configured on the interface, it will cut off the packet at the designated MTU, causing the server to receive a malformed packet, which will throw a CRC error.
If you have a layer 1 issue, you will see not on all but one or two nodes.
NEW QUESTION 29
An administrator is monitoring the Nutanix v5.15-based AOS cluster performance logs and notices that a SQL server VM is greatly exceeding its intended maximum IOPS.The administrator has confirmed that a QoS policy was previously created for the group of VMs this server is a member of.
What are two reasons that this VM would exceed its maximum configured IOPS from the QoS Policy?
(Choose two.)
- A. It was cloned from another SQL Server VM that was a member of the QoS Policy.
- B. The VM was not created as an AFS virtual machine.
- C. The SQL Server VM has volume groups attached.
- D. The VM is missing the required snapshot needed to implement the QoS Policy.
Answer: B,C
Explanation:
Explanation
Ref:https://portal.nutanix.com/page/documents/details?targetId=Prism-Central-Guide-Prism-v5_18:mul-storage-
NEW QUESTION 30
A consultant creates an AHV cluster and connects the Intel X550T NICs to the top of rack switch using Twinax cables. The activity and link lights are green. The cluster cannot communicate over the 10GbE link.
What is the first command the consultant should perform to troubleshoot the issue?
- A. manage_ovs show_bridges
- B. manage_ovs update_uplinks
- C. manage_ovs show_uplinks
- D. manage_ovs show_interfaces
Answer: A
NEW QUESTION 31
An administrator is responsible for the following Nutanix Enterprise Cloud environment:
* A central datacenter with a 20-node cluster with 1.5PB of storage
* Five remote sites each with a 4-node cluster with 200TB storage
The remote sites are connected to the datacenter via 1GB links with an average latency of 6 ms RTT. What is the minimum RPO the administrator can achieve for this environment?
- A. 6 hours
- B. 1 hour
- C. 15 minutes
- D. 0 minutes
Answer: C
Explanation:
Explanation
Ref:https://support-portal.nutanix.com/page/documents/details?targetId=Web-Console-Guide-Prism-v5_10:wc-p
NEW QUESTION 32
An administrator receives a notification that storage in a Nutanix cluster is unavailable. The cluster consists of five nodes and is configured with a Fault-Tolerance level of 1 (FT-1).
Upon investigation, the administrator finds the following:
* All AHV hosts are powered on and the CVMs are running
* Nodes A, B, and C are connected to one top of rack switch
* Nodes D and E are connected to a second top of rack switch
* The cluster status command run on Node A shows that CVM services on nodes D and E are down Which issue is causing the storage outage?
- A. The genesis process is down on both Nodes D and E.
- B. The default gateway for the CVMs and AHV hosts is down.
- C. Nodes D and E are inmaintenance mode.
- D. The switch connecting Nodes D and E is down.
Answer: D
Explanation:
https://hyperhci.com/2020/07/29/nutanix-cluster-services-down-troubleshooting/
NEW QUESTION 33
In a 20-node ESXi deployment, the customer needs additional resiliency to survive the loss of two nodes concurrently.
Which configuration should the consultant use to ensure that the appropriate resources are available?
- A. Storage reservation for 5%; HA admission control for 5%, cluster RF3
- B. Storage reservation for 10%; HA admission control for 10%, cluster RF2
- C. Storage reservation for 5%; HA admission control for 5%, cluster RF2
- D. Storage reservation for 10%; HA admission control for 10%, cluster RF3
Answer: D
NEW QUESTION 34
A consultant creates a Nutanix cluster using the 10.10.10.0/24 network and VLAN 10. The customer creates a VM network inside the Prism using VLAN 20. The customer starts to create VMs but is unable to ping the default gateway from these new systems.
What is causing the issue?
- A. The CVM/hypervisor cannot use the same VLAN as guest VMs.
- B. The switch port is not set up as a trunk.
- C. Only one VLAN is supported on AHV.
- D. The CVM/hypervisor must be on an untagged VLAN.
Answer: B
NEW QUESTION 35
An administrator is deploying an application that requires maximum I/O throughput for scratch data. The administrator is concerned that the throughput requirement is greater than what can be provided by asingle cluster node.
What should the administrator do to meet this requirement?
- A. Create a volume group with one virtual disk attached to the VM
- B. Create a volume group with several virtual disks and attach to the VM
- C. Create a virtual disk attached tothe VM's PCI interface
- D. Create several virtual disks attached to the VM's virtual SCSI controller
Answer: B
Explanation:
Explanation
Ref:https://next.nutanix.com/community-blog-40/scaling-up-vm-storage-performance-on-ahv-volume-group-loa
NEW QUESTION 36
An administrator has two clusters: Site A and Site B.
Async DR is configured between the clusters as follows:
* Site A is the Primary Site
* Site B is the Secondary inactive Site, no VMs running
* Site A is fully in Production
* Site B used as Backup/Disaster Recovery
The customer wants to perform a planned failover between the sites.
How should the administrator accomplish this?
- A. Click Activate on the Secondary site within the Data Protection Dashboard
- B. Choose Migrate on the Secondary site within the Data Protection Dashboard
- C. Click Activate on the Secondary site and run deactive NCLI command on Primary site
- D. Choose Migrate on the Primary sitewithin the Data Protection Dashboard
Answer: D
Explanation:
Explanation
Ref:https://portal.nutanix.com/page/documents/details?targetId=Web-Console-Guide-Prism-v510:wc-protection-
NEW QUESTION 37
An administrator is deploying Nutanix Files 3.5 and needs to configure the sizing of the FSVMs for an increased number of concurrent SMB connections over the default 750.
What should the administrator do?
- A. During installation, click Customize on the File Server Installation screen, change the number of connections, and finish the installation
- B. Complete the default installation change the CPU and RAM m Prism, and then log into the File Server dashboard and change the Filer Server Properties
- C. Deploy the Files VMs.power down the three FSVMs. change the CPU and RAM via Prism, and then power the three FSVMs back up
- D. During installation, input the correct number of connections in the File Server Installation screen and complete the installation
Answer: A
Explanation:
Explanation
Ref:https://portal.nutanix.com/page/documents/details?targetId=Files-v3_6:fil-file-server-manage-c.html
NEW QUESTION 38
Refer to the exhibit.
An administrator creates a security policy that isolates their financial application from accessing the Internet When viewing the policy in Prism Central, several connections from the application are outbound to the Internet.
What is causing this issue with the policy?
- A. The blockedconnections are illustrated for information only.
- B. The policy has been left in monitor mode instead of enforcing mode.
- C. The Activate box was not checked in the rule, so it is not enforcing.
- D. The 0.0.0.0 address was not specified in the outbound rule.
Answer: B
Explanation:
Explanation
https://portal.nutanix.com/page/documents/details?targetId=Prism-Central-Guide-Prism-v510:mul-security-polic
NEW QUESTION 39
Refer to the exhibit.
After performing ESXi to AHV conversion on a cluster, the alerts shown in the exhibit display on Prism. What should the administrator do to resolve this issue efficiently?
- A. Remove VMs from the Protection Domain and add them back in.
- B. Create a new Protection Domain and add the VMs to rt.
- C. Remove the VMs. create a new Protection Domain, and add VMs to it
- D. Delete the Protection Domain, create a new Protection Domain, and add the VMs to it
Answer: A
NEW QUESTION 40
An administrator is deploying an application using Nutanix Volumes. After configuring the volume group and connecting the guest's iSCSI initiator to the volume group, they begin performance testing.
The administrator learns that performance on the virtual disk attached to the iSCSI initiator is far less than that of a virtual disk connected directly to the VM.
Which situation is causing this condition?
- A. The VM's iSCSI traffic is being routed to the data services IP subnet
- B. Data Locality ensures that VM attached disks are always faster than iSCSI volumes.
- C. The performance test is generating small block random 10.
- D. The duster data services IP address is a bottleneck, shared with other iSCSI traffic
Answer: D
NEW QUESTION 41
A customer has a G6 AHV cluster with 4x10GbE NICs on each node and the following configuration:
* Networking is set to default
* Only two NICs are connected
The customer receives the following critical message:
The NIC is disconnected from the switch, or the switchport is failing.
What should the consultant verify to resolve the issue?
- A. The NICs are configured for active-backup.
- B. The VLANs are configured correctly on the switch or tagged on the cluster.
- C. The NICs are connected for balance-slb.
- D. The other two 10GbE connections are removed from the default bond.
Answer: A
NEW QUESTION 42
An administrator receives reports that VDI desktop performance in an 8-nodeNutanix VDI environment is poor. Opening applications takes between 1 and 2 minutes.
When investigating the issue, the following conditions are found:
* Cluster memory utilization: 80%
* Cluster SSD utilization: 70%
* Average VM CPU Wait Time: 11%
*CVM CPU utilization: 75%
Which action should be taken to improve VDI performance?
- A. Add CPU resources to the cluster.
- B. Increase the amount of SSD storage in the cluster.
- C. Increase the number of vCPU cores allocated to the CVM.
- D. Add memory to the nodes in the cluster.
Answer: A
NEW QUESTION 43
A consultant is preparing to add new nodes into an existing cluster. The current cluster AOS version is 5.8.
The new expansion node is currently running AOS 5.9 code. The cluster must continue to run at its current AOS version.
Which method can be used to successfully add the node?
- A. Use the CLI and enter cluster add-node node-serial="node_serial".
- B. Upgrade the cluster to 5.9 and add the node through Prism Element.
- C. Use Prism Element to Expand the cluster and select the re-image option.
- D. Use Prism Element, which will downgrade the node by default during the node add process.
Answer: C
NEW QUESTION 44
An administrator needs to migrate workloads from a Nutanix cluster running VMware ESXi to Nutanix AHV.
The migration process needs to be completed in multiple VM groups and support roll back in caseany problems are found during user acceptance testing.
Which action should the administrator perform?
- A. Use VMware Converter
- B. Use Nutanix one-click cluster conversion from ESXi to AHV
- C. Usestorage live migration
- D. Use Cross Hypervisor DR to replicate VMs from ESXi to AHV
Answer: B
Explanation:
Explanation
Ref:https://next.nutanix.com/installation-configuration-23/convert-existing-nutanix-vmware-cluster-to-nutanix-o
NEW QUESTION 45
Refer to the exhibit.
A Microsoft SQL 2016 deployment is shown in the exhibit. The administrator receives user reports that database queries take too long to return.
Which optimization should be made to this configuration to improve performance?
- A. Configure the VM to use a PCI disk controller
- B. Combine both of the OS and SQL Binaries disks
- C. Add a second SCSI controller for the Database.
- D. TempDB, andLogs disk Separate the Database. TempDB, and Logs onto their own disks
Answer: D
NEW QUESTION 46
Refer to the exhibit.
A system administrator is using Range-Autofill tool to assign IP addresses to setup a multi-block cluster based on the following configuration:
Which additional changes must be made during the Foundation process to configure the cluster correctly?
- A. Reorder block serial
- B. Reorder blocks
- C. Change host names
- D. Change IP address
Answer: C
NEW QUESTION 47
An administrator needs to configure snapshots for DRscenarios. The databases get refreshed on Friday nights regularly. The search service application re-indexes the new application on Saturday nights regularly. The remaining front-end and middle tier VMs are static but do get minor version updates weekly.
The administrator needs to have 2 weeks of daily snapshots for all the VMs in an app group and 2 weeks application consist local snapshots only on Fridays, Saturdays and Sundays on the same group of VMs.
Which two options should the administrator use to configure snapshots?
- A. Create a schedule in a protection domain for all applicable VMs to snap daily with application consistency enabled with 6 days of retention and with no application consistency and 14 days local retention.
- B. Create a protection domain forall VMs
- C. Create one protection domain for all VMsin an application group with scheduled daily non-application consistent snapshots and another protection domain for all VMs in an application group with scheduled Friday. Saturday, Sunday application consistent snapshots.
- D. Create two consistency groups in a protection domain, one for front-end and middle tier apps with no application consistency, one for database and Search apps with application consistency, and apply the correct schedule to both groups.
Answer: B
NEW QUESTION 48
A consultant configures an ESXi cluster which will utilize a vSphere Distributed Switch (vDS). The consultant has just migrated the first host to the dvSwitch when several alerts appear within Prism Element regarding Host-to-CVM connectivity.
What is causing these alerts?
- A. The consultant migrated the CVM Backplane and VM network adapter over to the vDS.
- B. VLAN tags are incorrectly configured on the vDS port groups.
- C. The consultant migrated the CVM svm-iscsi-pg network adapter over to the vDS.
- D. The consultant migrated the CVM Backplane network adapter over to the vDS.
Answer: D
NEW QUESTION 49
......
Verified NCS-Core Exam Dumps Q&As - Provide NCS-Core with Correct Answers: https://www.braindumpspass.com/Nutanix/NCS-Core-practice-exam-dumps.html
NCS-Core Exam Questions | Real NCS-Core Practice Dumps: https://drive.google.com/open?id=1XgXLawmCCuPly2C6xF48ltFylJU1pkYb